Differential Pressure Flowmeter
for measuring steam, gas and liquids

deltaflow pitot tube

deltaflow pitot tube: flow meter for gas, steam and liquids

The deltaflow differential pressure flowmeter (dp) is a cost- and energy efficient flowmeter for gases, liquids and steam.

Due to the special probe profile the deltaflow pitot tube can assure the highest level of precision and excellent process liability, even under extreme conditions. Averaging pitot tubes are causing the lowest pressure loss of all dp-flow meters and are therefore highly energy efficient. The deltaflow differential pressure flowmeter for steam, gas and liquids has been installed several ten thousand times in all industrial fields. Compared with traditional ISO 5167 primary elements such as orifices or venturis, deltaflow is not only saving energy but is also more inexpensive and causes less mounting costs. deltaflows high tolerance on non ideal flow profiles ensures high accuracies even under short inlet conditions.

Typical applications are flow measurement of steam, the metering of perssurized air, liquid flow measurements of water, oil, benzene. deltaflow is used to measure stack gas and flare gas, natural gas, bio gas and many more…

The deltaflow averaging pitot tubes are used in thousands of industrial plants such as power plants, sewage plants, breweries, automotive plants, steel plants… For the calculation and design the deltaflow flowmeter a self-explanatory software is free for your download.

 
  Product Summary

Fluids Gas, Steam
  Liquids
Pipe Sizes 1..25 mm deltaflow DF8
  20..100mm deltaflow DF12
  80..2500mm deltaflow DF25
  200..15000mm deltaflow DF44
Operating conditions –200 bis zu 1240 °C
  0..690 bar
  Pure to extremely contaminated, aggressive media
  Eex ia, ATEX
Certificates ATEX
  PED 97/23/EC, TRD
  2.2 / 3.1 / 3.2 (EN 10204)
 
  Contact
Desired Informations
steam flow meter deltaflow

Advantages of differential pressure flow measurement with the deltaflow dynamic pressure probe compared to orifices, venturis and nozzles according to ISO 5167 or DIN 1952:

  • Low pressure drop, therefore high energy saving potential
  • Easier to install, no need to disconnect pipework
  • Low weight even for large diameters
  • Very high accuracy (deltaflow from 0.4%)
  • Very high measurement dynamics, up to 1:30 depending on application
  • Highly resistant to dirt and condensate
  • Low initial cost, even for large diameters
  • Proven principle

Flow measurement with the deltaflow dynamic pressure probe is based on the same principles as classic primary elements (orifice, venturi, nozzle), so integration into a measurement computer or DCS is straightforward.

Multi-task connection - patented flexibility for dp flow measurement

Every pitot tube needs a connection system that transmits the differential pressure from the probe to the analyser, the differential pressure transmitter. The connection system for our deltaflow is special: it can be easily adapted to different applications, whether you want to measure gas, steam or liquids.

How does it work? The deltaflow connection consists of a head and two universal adapters. These components are identical for all media. We customise the head for you so that the deltaflow fits your application perfectly.

This multi-tasking concept has an additional advantage when measuring steam flow:

You don't need expensive additional condensate vessels. We have dimensioned the volume of the connection adapters to ensure sufficient vapour condensation at all times. And we have reduced the condensate slope - the cause of large measurement errors in the part-load range - by a factor of 10 compared to conventional traps. This means that differential pressure measurement is accurate down to the smallest flow rate, even at partial load with steam. That makes deltaflow a very accurate steam flow meter.

deltaflow: the economic and ecologic flow meter solution

Compared to classical primary elements such as venturi, orifice or nozzle, the deltaflow differential pressure flowmeter is not only more accurate and reliable but saves also a huge amount of energy. Remembering that a single deltaflow in steam may save several kW of energy, one can imagine that deltaflow is not only saving money but also has an countable positive effect on the energy losses in industrial processes. This is not only econonmic but also reduces the world wide greenhouse effect.

Configure your deltaflow NOW!

Just go to your webshop and configure your deltaflow differential pressure flowmeter just in minutes.

>>webshop

 

deltaflow plus Multivariable SYS-MMF: This is an ultra compact, easy to use and inexpensive solution

multivariable transmitter with steam
Order the deltaflow pitot tube together with the multivariable transmitter SYS-MMF.
 
SYS-MMF not only measures the differential pressure, but also the absolute pressure P1 and the process temperature via the integrated PT100,. The SYS-MMF then internally calculates the p&T compensated mass flow (or standard volume flow) for gases and steam. A differential pressure mass flow measurement could hardly be integrated in a simpler, more compact and cheaper way. The SYS-MMF outputs the measuring current signal directly via its 4..20mA output.
 
Rufen Sie uns an.nehmen Sie mit uns Kontakt auf!