LSP1
Air-Flushing System for dust laden gases
Used together with the deltaflow, the air-flushing system LSP1 permits the measurement of extremely dusty gases.
Connected to the deltaflow and the dp-transmitter, the LSP1 cleans the channels of the probe efficiently from dust, dirt and condensation.
The LSP1 has been developed and tested in close co-operation with leading power plant operators and is also used successfully for security installations and cut-off installations.
Applications
Primary, secondary and recycled air-volume-measurement,
measurement of waste-gas volume in the chemical industry,
power plants and incineration plants.
Dusty return air from the production
Air containing cement
Blast furnace gas, coke-gas, throat-gas
Maintenance intensive primary cells like venturis, orifices,
nozzles can be equipped subsequently
PRODUCT SUMMARY
Supply | 230VAC (optional 24VDC ), 6bar compressed air |
Size (BxHxT) | 250 × 400 × 120 mm |
Adjustment of the flushing time | Potentiometer |
Adjustment of the flushing intervals | Bridges |
Pneumatic connections | Ermeto or pressure hose fitting, others upon request |
Electrical connections | PG 13,5 or others upon request |
DOWNLOADS